There are three widely used ways to test emergency lighting. To understand them it is necessary to understand first how an emergency light fitting is wired. Note that the remarks that follow apply to self-contained emergency fittings, not to central battery operated emergency fittings. First floor has a conference room, dining area, servery and kitchen with adjourning conveniences, 11 rooms (classroom or meeting/training rooms), 5 office rooms and 3 sets of conveniences. You need emergency lighting in areas that could be considered “dangerous” such as commercial kitchens or plant rooms. If your building has rooms larger than 60 square metres, then emergency lighting is recommended. How long do emergency lights need to stay on? Details of the emergency lighting system, including its location, components, and the type of system installed.

Yes if you are testing/servicing on the discharge test then no lights would be a problem for persons working in those areas and so this would need doing when unoccupied - so I can see the logic behind the key switches not shutting off power - but that would only be for green LEDs and not red LEDs that would be difficult to visually see - similar if 3 tube lighting is working and one of the tubes is the EL light you wouldn't know if that EL unit was working if the main lights are still being powered... Our experienced testers conduct over 14,000 emergency lighting tests every year in properties across the UK. They test and inspect all units to ensure they’re functioning correctly. Pre-service audit

Tenant Liaison

UK fire safety legislation states that emergency lighting is required in buildings to provide light if normal lighting fails during a fire.

They can also provide insights on the suitability of systems in respect of applicable British standards and codes. After this full discharge test, precautions must be taken as the batteries can take up to 24 hours to recharge and so the premises should not be occupied until everything is restored. For many buildings it is possible to do this over the weekend, but for flats and other premises which are occupied full time, there will need to be other arrangements whilst the batteries are recharging. L SW is the normal mains supply. A normal light switch, or sensor, would usually be on this circuit to enable the end-user to have control over the light fitting in normal operating mode. L SW is always to be wired so that any switching of L PERM will disconnect L SW too, but any switching of L SW will not affect L PERM. An Emergency Lighting Certificate is a document that certifies that the emergency lighting system in a building has been installed, tested and commissioned in accordance with the relevant regulations and standards. The certificate is issued by a qualified electrician or contractor who has carried out the installation and testing of the emergency lighting system. A minimum duration of 3 hours should be used for emergency escape lighting if the premises are not evacuated immediately. The 3 hour time frame allows the fire brigade time to work in the event of a fire after all of the building’s occupants have been safely evacuated. How often should my emergency lighting system be tested?There are different types of emergency lighting; it can be maintained, non-maintained, or combined. Often there are choices with how long they remain on after a power failure. Maintained Emergency Lighting We can provide emergency lighting testing and servicing to ensure you are fire safety compliant. We can test your emergency lighting system at a time that suits you. The results of all testing and any necessary corrective action can be recorded in your fire safety logbook. This record is then available for inspection if required.

It's swings and roundabouts in the building as some areas the key switch shuts off the power to the lights (per room, location) and illuminates the EL. The new refurbished areas the key switch does not cut power to the lights, and with some EL units being part of the main lights this poses a problem to actually see if they are working or not. Yes they have green LEDs in them but you have to look closely to see if they are actually coming on as required. High risk task area lighting provides light for the safety of people involved in potentially dangerous processes. This lighting enables proper shut-down procedures to be followed for the safety of the operator and other occupants of a building. The needs of every building must be outlined in a fire risk assessment. This fire risk assessment needs to be reassessed every year to ensure it meets the changing needs of the premises. British Standards and Codes detail the nature and installation of emergency escape lighting systems. Yes and no. If it is a small building and all the emergency lights are on one circuit, then yes, you have no choice. However if it is a large building then it would make sense to stagger the testing. This way the whole building would not be affected if there was a power cut, during the recharge time. Testing Central Battery Systems

How is an Emergency Lighting Test Conducted?

A key-switch. This is installed on the permanent live supply to an emergency fitting. When actuated it isolates the emergency fitting, thus simulating a power failure. The team here at Fire Trade Supplies have assembled a collection of Fish Key Emergency Lighting including F9099 grid keys (PK6), Multi-EL (3 pairs of assorted EL keys), EL key - crabtree style (PK6) as well as many more combinations which can all be found in our store. Is your building permanently used E.G. Hotels, then you need to test the lights so that the end of the test corresponds to the start of day. In this way the emergency lights will have a good time to recharge during daylight hours. Natural daylight will help if the emergency lights don’t last 3 hours. Should I test ALL emergency lights at once?

This means that the emergency light fitting works with the main lights and is connected to the other lights and is controlled with the normal lighting. When the power fails, the emergency light remains on through the battery which has been charged whilst the mains is on. It can also be turned off whilst the mains is on if it is not needed. The battery often emits around 10% of the normal light levels. Non-Maintained Emergency Lighting If you have a central battery system, then most of the above still applies to you. Drop the incoming power to the battery and do the same walk tests. Make a note of any failures etc. However you need to test the whole system all at once. By testing the whole system at once, you are ensuring that the battery can power all the emergency lights for a full 3 hour duration. If you only tested in zones then the battery would not get a full and proper test.In my humble opinion the switch should be of "simulation" status IE cutting power (as it would if in a power cut, fire, etc.) and illuminating EL only. Confirmation that the emergency lighting system has been designed and installed to meet the specific requirements of the building and its occupants.